Wall Gauging & NDT for Drawn Shells
深冲壳体的壁厚与探伤检测
标签:检测标准, 壁厚公差, 超声, 水压试验, 质量控制
深冲壳体的常规检测组合:①壁厚——接触式超声测厚(ASTM E797 方法),高频探头沿壳体轴向分 8 环、每环 4 点测,壁厚公差通常按 ±8% 验收;②内部缺陷——X 射线查底部与侧壁夹渣、气孔;③承密性——水压试验取 1.5 倍工作压力保压 5 min 无渗。首件检验(FAI)记录全部数据并封样,量产每 500 件抽 1 件复测壁厚。铜壳无磁性,不能用磁粉探伤,荧光渗透或涡流是表面裂纹的替代方案。
The routine inspection set for drawn shells: (1) wall thickness by contact ultrasonics (ASTM E797), a high-frequency probe reading 8 axial rings × 4 points; ±8% of nominal is a typical tolerance. (2) Internal soundness — X-ray the base and wall for inclusions and porosity. (3) Pressure-tightness — hydro test at 1.5× working pressure for 5 min. Full first-article data is archived with a retained sample; re-check one shell per 500 in production. Copper is non-magnetic, so no MPI — use fluorescent penetrant or eddy current for surface cracks.